cmdVAL_GETIndex

Command Code:

The Packet:

Description:

This command retrieves a system parameter.  A parameter ID that is out of range will generate an error message.  The reply packet echoes the Parameter ID in the first data byte and contains the system value in the remaining byte(s).

All system parameters are one or two bytes in size.  Some parameters are read-only.  The table below lists the values associated with this command and their access modes and sizes.

  ParamID Description Access Size
0 Module IIC Address r/w 1
1 Router IIC Address r/w 1
2 Heartbeat Rate r/w 1
3 IIC Baud Rate r/w 1
4 Serial Baud Rate r/w 1
5 Heartbeat Mode r/w 1
6 Boot Reflex Flag r/w 1
7 Link-down Reflex Flag r/w 1
8 Firmware Version r 2
9 Build Number r 2
10 Board Type r 1
11 First 2 SN bytes r 2
12 Last 2 SN bytes r 2
13 TEA File Slots r 1
14 TEA File Bytes r 2
15 VM Boot File 1 r/w 1
16 VM Boot File 2 r/w 1
17 VM Boot File 3 r/w 1
18 VM Boot File 4 r/w 1
19* Serial Relay Flag r/w 1
20* Quiet Mode Flag r/w 1
21* Serial Timeout r/w 1

* This feature is only available in new BrainStem modules or BrainStem GP 1.0 modules with firmware Build 9 or higer.

Related:


version: 1.0, build 80903
© Copyright 1994-2008 Acroname, Inc., Boulder, Colorado.  All rights reserved.